Welcome to YUANYEE's official website!

Diesel Transfer Pump(YY-40)

  • Voltage: DC12 or 24V
  • Rated Input Power: 160w
  • No-load speed: 3200RPM
  • Max pump rate: 40L/min
  • Max.Height: 10m
  • Max.Depth: 2m
  • Fitting: BSPF/NPT 1
  • Power cable: With 1.5M of Battery cable clamp Only for diesel,Self-priming
  • MEAS/PCS: 27*17*20cm
  • G.N/W: 4/3.5Kg

Efficiently and safely perform storage, refueling, replacement, and transfer of various fuels. Compatible with fuels of different viscosities and complex operational environments, featuring explosion-proof, leak-proof, and corrosion-resistant safety protections. Meets compliance requirements for fuel transfer across diverse scenarios.

Send Inquiry

Product Description

Voltage: DC12 or 24V

Rated Input Power: 160w

No-load speed: 3200RPM

Max pump rate: 40L/min

Max.Height: 10m

Max.Depth: 2m

Fitting: BSPF/NPT 1

Power cable: With 1.5M of Battery cable clamp Only for diesel,Self-priming

MEAS/PCS: 27*17*20cm

G.N/W: 4/3.5Kg

Efficiently and safely perform storage, refueling, replacement, and transfer of various fuels. Compatible with fuels of different viscosities and complex operational environments, featuring explosion-proof, leak-proof, and corrosion-resistant safety protections. Meets compliance requirements for fuel transfer across diverse scenarios.

Specifications

Voltage DC12 or 24V
Rated Input Power 160w
No-load speed 3200RPM
Max pump rate 40L/min
Max.Height 10m
Max.Depth 2m
Fitting BSPF/NPT 1
Power cable With 1.5M of Battery cable clamp Only for diesel,Self-priming
MEAS/PCS 27*17*20cm
G.N/W 4/3.5Kg

Application

Covering industrial production (factory oil storage and transfer, mining machinery refueling), transportation (logistics fleets, vessel fueling), agricultural operations (farm machinery refueling), emergency response (oil spill recovery, outdoor equipment emergency refueling), and routine oil changes and cleaning for equipment like generator sets. Suitable for both stationary and mobile operations.

Support

Help & Support

To ensure long-term reliability and performance of the YY-40 diesel transfer pump , users can access the following technical assistance and after-sales services:

 

  1. Installation Guidance

    • Provides standard wiring diagrams and fuel line layout recommendations.

    • Remote technical support (via document or video) can be arranged to ensure correct installation and proper sealing.

  2. Troubleshooting

    • If the pump fails to start, check the power supply, voltage stability, and fuse condition.

    • If abnormal noise or insufficient pressure occurs, verify whether the fuel line is blocked or the filter element is clogged.

    • If fuel leakage is detected, stop operation immediately and inspect seals or mounting alignment.

  3. Maintenance & Replacement

    • Always use genuine or certified replacement parts.

    • Follow the manufacturer’s maintenance schedule, regularly clean filters, and check output pressure.

  4. Contact & Service Channels

    • Technical consultation, repair service, and training are available through authorized distributors or official service centers.

    • For technical documents (installation manuals, 3D models, performance curves, etc.), contact your supplier or visit the manufacturer’s support portal.